日韩成人高清二区三区_亚洲成AV人片不卡无码_啊灬啊灬啊灬快灬高潮少妇_久久这里只有精品最新6_日韩欧美国产一区精品

首頁 >>> 產(chǎn)品目錄 >>> Field Communicator
儀表展覽網(wǎng) >>> 展館展區(qū) >>> Yokogawa Field Control Unit A2FV50S-A314000
> Yokogawa Field Control Unit A2FV50S-A314000

產(chǎn)品資料

Yokogawa Field Control Unit A2FV50S-A314000[產(chǎn)品打印頁面]

Yokogawa Field Control Unit A2FV50S-A314000
  • 如果您對該產(chǎn)品感興趣的話,可以
  • 產(chǎn)品名稱:Yokogawa Field Control Unit A2FV50S-A314000
  • 產(chǎn)品型號:A2FV50S-A314000
  • 產(chǎn)品展商:Yokogawa
  • 產(chǎn)品文檔:無相關(guān)文檔
簡單介紹
Yokogawa Field Control Unit A2FV50S-A314000. Please contact us: tekrachel @ 163.com
產(chǎn)品描述

Manufacturer: Yokogawa Electric Corporation

Yokogawa Field Control Unit A2FV50S-A314000

A Field Control Unit (FCU) which is the intelligent part of the Field Control Station (FCS). This product supports both N-IO and FIO. However, only the communication module is supported among the I/O modules for FIO.

Weight for Yokogawa Field Control Unit A2FV50S-A314000

A2FV50S: Approx. 6.9 kg. 

A2FV50D: Approx. 7.7 kg.

Model and Suffix Codes for Yokogawa Field Control Unit A2FV50S-A314000

Field Control Unit

Description

Model

A2FV50S

Field Control Unit (for N-IO, 19-inch Rack Mountable)

Suffix

Codes

-A

Standard type (for CP471) (*1)

-S

Standard type (for CP461) (*3)

3

Dual-redundant Vnet/IP, single power supply

4

Dual-redundant Vnet/IP, dual-redundant power supply

1

Always 1

1

100 - 120 V AC power supply (*4)

2

220 - 240 V AC power supply (*4)

4

24 V DC power supply (*4)

0

With no explosion protection

1

With explosion protection

0

Basic type

1

With ISA Standard G3 option

0

Always 0

Option

Code

/ATDOC

Explosion Protection Manual (*5)

/MRN

With Marine Standards (*2)

*1:      CP471 operates with CENTUM VP R6.01 or later version of Control Function for Field Control Station. Be sure to apply the software patch for supporting CP471 for CENTUM VP R6.01, R6.02, R6.03, and R6.04. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN.

*2:      Select the option code “/MRN if A2FV50¨ with marine standards is required.

*3:      Unavailable for ordering A2FV50S with CP461 due to the supply ends on October 19, 2019. Existing CP461 can be replaced with CP471. Replacement from CP461 to CP471 is prohibited to perform by a user. This replacement must be done by the service engineer authorized by Yokogawa Electric Corporation. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN. Yokogawa Field Control Unit A2FV50S-A314000

*4:      To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet.

*5:      Select the option code “/ATDOC to follow the ATEX Directive when any of N-IO components are used for explosion protection.

Duplexed Field Control Unit for Yokogawa Field Control Unit A2FV50S-A314000

Description

Model

A2FV50D

Duplexed Field Control Unit (for N-IO, 19-inch Rack Mountable)

Suffix

Codes

-A

Standard type (for CP471) (*1)

-S

Standard type (for CP461) (*3)

4

Dual-redundant Vnet/IP, dual-redundant power supply

1

Always 1

1

100 - 120 V AC power supply (*4)

2

220 - 240 V AC power supply (*4)

4

24 V DC power supply (*4)

0

With no explosion protection

1

With explosion protection

0

Basic type

1

With ISA Standard G3 option

0

Always 0

Option

Code

/ATDOC

Explosion Protection Manual (*5)

/MRN

With Marine Standards (*2)

*1:      CP471 operates with CENTUM VP R6.01 or later version of Control Function for Field Control Station. Be sure to apply the software patch for supporting CP471 for CENTUM VP R6.01, R6.02, R6.03, and R6.04. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN.

*2:      Select the option code “/MRN if A2FV50¨ with marine standards is required. 

*3:      Unavailable for ordering A2FV50D with CP461 due to the supply ends on October 19, 2019. Existing CP461 can be replaced with CP471. Replacement from CP461 to CP471 is prohibited to perform by a user

This replacement must be done by the service engineer authorized by Yokogawa Electric Corporation. CP471 can be combined with the style code S3 or later of ESB bus coupler module EC401. See GS 33J60E30-01EN.

*4:      To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet.

*5:      Select the option code “/ATDOC to follow the ATEX Directive when any of N-IO components are used for explosion protection.

產(chǎn)品留言
標(biāo)題
內(nèi)容
聯(lián)系人
聯(lián)系電話
電子郵件
公司名稱
聯(lián)系地址
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有必要,請您留下您的詳細(xì)聯(lián)系方式!